BYVJP - NICKEL CADMIUM BATTERY
- MSDS: BYVJP
- Manufacturer: RAYOVAC
- Product Name: NICKEL CADMIUM BATTERY
- National Stock Number: 6140-00N062958
Product Identification
Product ID:NICKEL CADMIUM BATTERY
MSDS Date:03/01/1986
FSC:6140
NIIN:00N062958
MSDS Number: BYVJP
Responsible Party
MADISON, WI 53711-0960
US
Emergency Phone: 608-275-4824
Info Phone: 608-275-4824
Preparer: T.J.A.
Cage: IO513
Contractor
Telephone: 608-275-4735/800-255-3924
Cage: 77542
Ingredients
NICKEL (SARA 313) (CERCLA)
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: 20-30%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3
CADMIUM (SARA 313) (CERCLA)
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: 13-15%
OSHA PEL 0.2 MG/M3 DUST
ACGIH TLV: 0.01 MG/M3 DUST
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
COBALT (SARA 313)
CAS: 7440-48-4
RTECS: GF8750000
Fraction By Weight: 1-2%
OSHA PEL 0.1 MG/M3
ACGIH TLV: 0.02 MG/M3
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 5-7%
OSHA PEL 2 MG/M3, C
ACGIH TLV: 2 MG/M3, C
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
RISK OF CHEMICALS TO MAN, VOL 52, PG 363,
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:NONE UNDER NORMAL CONDITION.
Explanation of Carcinogenicity:NICKEL:IARC MONOGRAPHS ON EVAL OF CARCIN
RISK OF CHEMS TO MAN, VOL 49, PG 257, 1990:GRP 2B. NTP 7TH ANNUAL
RPT (SUPDAT)
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . EYES:IMMEDIATELY FLUSH W/POTABLE WATER FOR A MINIMUM OF 15
MINUTES, SEEK ASSISTANCE FROM MD . SKIN:FLUSH W/COPIOUS AMOUN TS OF
WATER. CALL MD . INGEST:CONTACT THE NATIONAL CAPITOL POISON CENTER,
WASHINGTON D.C., (202) 625-3333 - CALL COLLECT.
Fire Fighting
Flash Point Method:OC
Extinguishing Media:WATER, FOAM, CO*2 - NO SPECIAL EXTINGUISHING MEDIA
REQUIRED.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . NICKEL & CADMIUM FUMES MAY BE RELEASED AT ELEVATED
TEMPERATURES (CADMIUM 500F, NICKEL 2500F).
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:BATTERIES ARE A DRY SOLID & CAN BE HANDLED
EASILY W/SHOVELS OR SIMILAR EQUIPMENT. WHEN ACCUMULATING LARGE
QUANTITIES OF UNDISCHARGED BATTERIES FOR DISPOSAL, PACK IN A
NON-CONDUCTIVE INSULATING MATERIA L.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE UNPACKAGED CELLS TOGETHER
SO CONTACTS CAN TOUCH. THIS SITUATION WILL RESULT IN CELL SHORTING
& HEAT BUILD-UP.
Other Precautions:DO NOT RECHARGE THIS TYPE OF BATTERY.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EX OF CARCIN:ON CARCINS, 1994:ANTIC TO BE CARCIN. HUMAN:LUNGS, NASAL
CAVITIES. CADMIUM:IARC MONO ON EVAL OF CARCIN RISK OF CHEMS TO MAN,
VOL 58, PG 119, 1193:GRP 1. NTP 7TH ANNUAL RPT ON CARCINS, 1994
:ANTIC TO BE CARCIN. OSHA REG. HUMAN:LUNG, PROSTATE, RENAL SYS
EFTS. COBALT:IARC MONOGRAPHS ON EVAL OF CARCIN (ING 5)
Chemical Properties
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:EXCESSIVE HEAT, ELECTRICAL SHORT.
Disposal
Waste Disposal Methods:DISPOSE ACCORDING TO APPROPRIATE LOCAL, STATE &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.