BYVJP - NICKEL CADMIUM BATTERY

  • MSDS: BYVJP
  • Manufacturer: RAYOVAC
  • Product Name: NICKEL CADMIUM BATTERY
  • National Stock Number: 6140-00N062958
Product Identification

Product ID:NICKEL CADMIUM BATTERY
MSDS Date:03/01/1986
FSC:6140
NIIN:00N062958
MSDS Number: BYVJP

Responsible Party
RAYOVAC
601 RAYOVAC DR
MADISON, WI 53711-0960
US

Emergency Phone: 608-275-4824

Info Phone: 608-275-4824

Preparer: T.J.A.

Cage: IO513

Contractor
RAYOVAC CORP
MADISON, WI 53711 US

Telephone: 608-275-4735/800-255-3924

Cage: 77542

Ingredients

NICKEL (SARA 313) (CERCLA)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 20-30%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3


CADMIUM (SARA 313) (CERCLA)

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: 13-15%

OSHA PEL 0.2 MG/M3 DUST

ACGIH TLV: 0.01 MG/M3 DUST

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


COBALT (SARA 313)

CAS: 7440-48-4

RTECS: GF8750000

Fraction By Weight: 1-2%

OSHA PEL 0.1 MG/M3

ACGIH TLV: 0.02 MG/M3


POTASSIUM HYDROXIDE (CERCLA)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 5-7%

OSHA PEL 2 MG/M3, C

ACGIH TLV: 2 MG/M3, C

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


RISK OF CHEMICALS TO MAN, VOL 52, PG 363,

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:NONE UNDER NORMAL CONDITION.
Explanation of Carcinogenicity:NICKEL:IARC MONOGRAPHS ON EVAL OF CARCIN
RISK OF CHEMS TO MAN, VOL 49, PG 257, 1990:GRP 2B. NTP 7TH ANNUAL
RPT (SUPDAT)
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . EYES:IMMEDIATELY FLUSH W/POTABLE WATER FOR A MINIMUM OF 15
MINUTES, SEEK ASSISTANCE FROM MD . SKIN:FLUSH W/COPIOUS AMOUN TS OF
WATER. CALL MD . INGEST:CONTACT THE NATIONAL CAPITOL POISON CENTER,
WASHINGTON D.C., (202) 625-3333 - CALL COLLECT.

Fire Fighting

Flash Point Method:OC
Extinguishing Media:WATER, FOAM, CO*2 - NO SPECIAL EXTINGUISHING MEDIA
REQUIRED.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . NICKEL & CADMIUM FUMES MAY BE RELEASED AT ELEVATED
TEMPERATURES (CADMIUM 500F, NICKEL 2500F).
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:BATTERIES ARE A DRY SOLID & CAN BE HANDLED
EASILY W/SHOVELS OR SIMILAR EQUIPMENT. WHEN ACCUMULATING LARGE
QUANTITIES OF UNDISCHARGED BATTERIES FOR DISPOSAL, PACK IN A
NON-CONDUCTIVE INSULATING MATERIA L.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE UNPACKAGED CELLS TOGETHER
SO CONTACTS CAN TOUCH. THIS SITUATION WILL RESULT IN CELL SHORTING
& HEAT BUILD-UP.
Other Precautions:DO NOT RECHARGE THIS TYPE OF BATTERY.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EX OF CARCIN:ON CARCINS, 1994:ANTIC TO BE CARCIN. HUMAN:LUNGS, NASAL
CAVITIES. CADMIUM:IARC MONO ON EVAL OF CARCIN RISK OF CHEMS TO MAN,
VOL 58, PG 119, 1193:GRP 1. NTP 7TH ANNUAL RPT ON CARCINS, 1994
:ANTIC TO BE CARCIN. OSHA REG. HUMAN:LUNG, PROSTATE, RENAL SYS
EFTS. COBALT:IARC MONOGRAPHS ON EVAL OF CARCIN (ING 5)

Chemical Properties

Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:EXCESSIVE HEAT, ELECTRICAL SHORT.

Disposal

Waste Disposal Methods:DISPOSE ACCORDING TO APPROPRIATE LOCAL, STATE &
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.